Emergency Flight Procedures
Emergency Controls:
E-STOP


PRESSING THE FLIGHT TERMINATION E-STOP WILL CUT POWER TO THE DRONE COMPLETLEY. IF THE DRONE IS IN THE AIR, IT WILL FALL OUT THE SKY. DO NOT PRESS EXCEPT FOR EMERGENCIES. KEEP THE SAFTEY FLAP CLOSED.
The E-Stop sets aside all the flight software, and causes immediate disarming of the vehicle no matter what state the vehicle is in.
RTL

The "RTL" (Return to Launchsite) flight mode will cause the vehilce to autonmously climb to a set altitude, and fly the shortest staight path back to it's take off point and autonmously land.
Manual Procedures
Loss of Video
Change to "Position Flight Mode"
Remove FPV Goggle & View GCS Screen
Begin Instrument Flight or if possible line of sight flight back to the landing zone
If in doubt, switch flight mode to "RTL"
Powertrain Failure
Lower Throttle Immediately
Announce "Dead Drone"
If there's enough altitude, give small stick movements to see if control can be regained
If Altitude is insufficient and/or control can not be regained, Press the E-Stop Button Immediately
Inflight Powerless
Lower Throttle Immediately
Announce "Dead Drone"
Press the E-Stop Button
Autonomous Failsafe:
Low Battery
20% Battery Level
Drone will give "Low Battery" warning to operator via GCS software.
15% Battery Level
Drone will begin autonomous RTL
5% Battery Level
If RTL is overrode and the drone is operating down to 5% battery, the drone will begin emergency decent and land autonomously.
Loss of Signal
Loss of GCS Signal
If disconnected for 5 seconds or more, drone will begin autonomous RTL until GCS signal is reestablished.
Loss of RC C2 Signal
After 1 second, drone will begin Autonomous RTL.
Last updated